Assessment Year | 2008 |
---|---|
Principal Product | Repaired & Remanufactured |
NAICS | 322219: Other Paperboard Container Manufacturing |
SIC | 7699: Repair Shops and Related Services, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 57 |
Plant Area |
300,000
ft2
|
Annual Production | 750,000
pieces
|
Production Hrs. Annual | 2,418
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $199,201 | 1,404,361 |
kWh
|
$0.14 |
Natural Gas | $764,984 | 70,718 |
MMBtu
|
$10.82 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $138,821 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2135: Repair and eliminate steam leaks | $4,006 | - |
$4,006
27,473
kWh
|
- | |
02 | 2.2443: Re-use or recycle hot or cold process exhaust air | $27,148 | $12,102 | - |
$27,148
-
MMBtu
|
|
03 | 2.4133: Use most efficient type of electric motors | $428 | $728 |
$428
2,936
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,858 | $16,291 |
$6,858
47,024
kWh
|
- | |
05 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $5,290 | $16,144 |
$5,290
18,135
kWh
|
- | |
06 | 2.2414: Use waste heat from hot flue gases to preheat | $71,962 | $222,664 | - |
$71,962
-
MMBtu
|
|
07 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $1,645 | $6,343 |
$1,645
11,278
kWh
|
- | |
08 | 2.2114: Shut off steam traps on super heated steam lines when not in use | $1,741 | - | - |
$1,741
-
MMBtu
|
|
09 | 2.2135: Repair and eliminate steam leaks | $1,347 | $140 | - |
$1,347
-
MMBtu
|
|
10 | 2.2113: Repair or replace steam traps | $3,011 | $294 | - |
$3,011
-
MMBtu
|
|
11 | 2.2136: Install / repair insulation on steam lines | $4,263 | $2,834 | - |
$4,263
-
MMBtu
|
|
12 | 2.4224: Upgrade controls on compressors | $8,305 | $25,703 |
$8,305
54,359
kWh
|
- | |
13 | 2.2414: Use waste heat from hot flue gases to preheat | $2,817 | $15,233 | - |
$2,817
-
MMBtu
|
|
TOTAL RECOMMENDED | $138,821 | $318,476 |
$26,532
161,205
kWh
|
$112,289
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs