| Assessment Year | 1988 |
|---|---|
| Principal Product | LUBRICATION EQUIPMENT |
| NAICS |
n/a
|
| SIC | 3569: General Industrial Machinery and Equipment, Not Elsewhere |
| Sales Range | $10 M to 50M |
| # of Employees | 140 |
| Plant Area |
n/a
|
| Annual Production | 65,000
pieces
|
| Production Hrs. Annual | 2,288
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $77,783 | 1,482,122 |
kWh
|
$0.052 |
| Natural Gas | $34,359 | 6,667 |
MMBtu
|
$5.15 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $31,501 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $26,406 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7123: Keep lamps and reflectors clean | $15,953 | $64,009 |
$15,953
300,996
kWh
|
- | |
| 02 | 2.7261: Install timers and/or thermostats | $5,095 | $560 |
$5,095
96,131
kWh
|
- | |
| 03 | 2.6232: Install set-back timers | $4,365 | - |
$4,365
82,356
kWh
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,122 | $180 |
$3,122
58,910
kWh
|
- | |
| 05 | 2.7243: Improve air circulation with destratification fans / other methods | $1,040 | $1,750 | - |
$1,040
-
MMBtu
|
|
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,926 | $575 |
$1,926
36,342
kWh
|
- | |
| TOTAL RECOMMENDED | $31,501 | $67,074 |
$30,461
574,735
kWh
|
$1,040
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $26,406 | $66,514 |
$25,366
478,604
kWh
|
$1,040
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs