Assessment Year | 1987 |
---|---|
Principal Product | INTERIOR TRIM PARTS(CAR) |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
n/a
|
Annual Production | 19,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $440,098 | 8,707,210 |
kWh
|
$0.051 |
Natural Gas | $105,509 | 22,461 |
MMBtu
|
$4.70 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $32,321 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,792 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $9,593 | $4,040 | - |
$9,593
-
MMBtu
|
|
02 | 2.7243: Improve air circulation with destratification fans / other methods | $3,581 | $16,250 | - |
$3,581
-
MMBtu
|
|
03 | 2.2511: Insulate bare equipment | $7,234 | $920 |
$7,234
141,852
kWh
|
- | |
04 | 2.6232: Install set-back timers | $6,113 | - |
$6,113
119,871
kWh
|
- | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,182 | - |
$2,182
42,790
kWh
|
- | |
06 | 2.2511: Insulate bare equipment | $1,839 | $1,160 |
$1,839
36,049
kWh
|
- | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,779 | $250 |
$1,779
34,877
kWh
|
- | |
TOTAL RECOMMENDED | $32,321 | $22,620 |
$19,147
375,439
kWh
|
$13,174
-
MMBtu
|
||
TOTAL IMPLEMENTED | $16,792 | $21,700 |
$3,618
70,926
kWh
|
$13,174
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs