Assessment Year | 1986 |
---|---|
Principal Product | WOOD BURNING STOVES |
NAICS |
n/a
|
SIC | 3433: Heating Equipment, Except Electric and Warm Air Furnaces |
Sales Range | $10 M to 50M |
# of Employees | 75 |
Plant Area |
n/a
|
Annual Production | 33,000
pieces
|
Production Hrs. Annual | 2,125
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $46,444 | 606,975 |
kWh
|
$0.077 |
LPG | $11,697 | 1,374 |
MMBtu
|
$8.51 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,855 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,175 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $4,032 | $8,712 |
$4,032
53,048
kWh
|
|
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,648 | - |
$1,648
21,688
kWh
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $881 | $120 |
$881
11,430
kWh
|
|
04 | 2.6232: Install set-back timers | $534 | - |
$534
7,034
kWh
|
|
05 | 2.4221: Install compressor air intakes in coolest locations | $537 | $236 |
$537
7,034
kWh
|
|
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $223 | $600 |
$223
2,931
kWh
|
|
TOTAL RECOMMENDED | $7,855 | $9,668 |
$7,855
103,165
kWh
|
||
TOTAL IMPLEMENTED | $2,175 | $956 |
$2,175
28,429
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs