| Assessment Year | 1986 |
|---|---|
| Principal Product | BOATS |
| NAICS |
n/a
|
| SIC | 3732: Boat Building and Repairing |
| Sales Range | $5 M to 10M |
| # of Employees | 45 |
| Plant Area |
n/a
|
| Annual Production | 500
pieces
|
| Production Hrs. Annual | 2,125
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $12,440 | 218,933 |
kWh
|
$0.057 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $1,780 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $227 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7111: Reduce illumination to minimum necessary levels | $890 | - |
$890
14,947
kWh
|
|
| 02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $366 | $400 |
$366
6,155
kWh
|
|
| 03 | 2.2437: Recover waste heat from equipment | $297 | $500 |
$297
4,982
kWh
|
|
| 04 | 2.6232: Install set-back timers | $227 | - |
$227
3,810
kWh
|
|
| TOTAL RECOMMENDED | $1,780 | $900 |
$1,780
29,894
kWh
|
||
| TOTAL IMPLEMENTED | $227 | - |
$227
3,810
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs