Assessment Year | 1988 |
---|---|
Principal Product | MEN AND BOYS JEANS |
NAICS |
n/a
|
SIC | 2325: Men's and Boys' Separate Trousers and Slacks |
Sales Range | $10 M to 50M |
# of Employees | 185 |
Plant Area |
n/a
|
Annual Production | 220,000
pieces
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $39,723 | 592,321 |
kWh
|
$0.067 |
Natural Gas | $2,772 | 583 |
MMBtu
|
$4.75 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,480 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,244 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $307 | $375 |
$307
4,689
kWh
|
- | - | |
02 | 2.2437: Recover waste heat from equipment | $1,159 | $1,070 | - |
$1,159
-
MMBtu
|
- | |
03 | 2.7261: Install timers and/or thermostats | $1,077 | $1,055 | - |
$1,077
-
MMBtu
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $180 | - |
$180
2,052
kWh
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $26 | $32 |
$26
586
kWh
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $731 | - |
$801
12,309
kWh
|
- | $(-70.0) | |
TOTAL RECOMMENDED | $3,480 | $2,532 |
$1,314
19,636
kWh
|
$2,236
-
MMBtu
|
$(-70.0) | ||
TOTAL IMPLEMENTED | $1,244 | $407 |
$1,314
19,636
kWh
|
- | $(-70.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs