| Assessment Year | 2005 |
|---|---|
| Principal Product | Beverage and Dairy Crates |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 70 |
| Plant Area |
125,000
ft2
|
| Annual Production | 6,370,000
pieces
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $973,112 | 14,994,071 |
kWh
|
$0.065 |
| Electricity Demand | $165,409 | 22,901 |
kW-mo/yr
|
$7.22 |
| Natural Gas | $9,820 | 1,100 |
MMBtu
|
$8.93 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $83,575 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.2511: Insulate bare equipment | $26,045 | $2,079 |
$26,045
421,742
kWh
|
- | - | - | |
| 02 | 3.5111: Filter and reuse hydraulic oil | $25,230 | $6,200 | - | - |
$25,230
-
gal
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $23,435 | $11,735 |
$20,765
336,257
kWh
|
$2,670
-
kW-mo/yr
|
- | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,725 | $55 |
$3,300
53,440
kWh
|
$425
-
kW-mo/yr
|
- | - | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $2,090 | $600 |
$1,750
28,279
kWh
|
$340
-
kW-mo/yr
|
- | - | |
| 06 | 2.7444: Close holes and openings in building such as broken windows | $1,170 | $1,575 |
$1,170
18,962
kWh
|
- | - | - | |
| 07 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $1,010 | - | - | - | - |
$1,010
-
lb
|
|
| 08 | 2.7135: Install occupancy sensors | $870 | $325 |
$870
14,126
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $83,575 | $22,569 |
$53,900
872,806
kWh
|
$3,435
-
kW-mo/yr
|
$25,230
-
gal
|
$1,010
-
lb
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs