Assessment Year 2001
Principal Product Missile Casing, Ordinance & Alum. For.
NAICS
n/a
SIC 3769: Guided Missile Space Vehicle Parts and Auxiliary Equipment, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 400
Plant Area 195,000
ft2
Annual Production 25,000,000
ton
Production Hrs. Annual 6,448
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $735,046 23,235,120
kWh
Electricity Demand $172,995 54,401
kW-mo/yr
Electricity Fees $87,192 -
Natural Gas $1,201,382 175,233
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $469,224 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $465,114

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.1224: Replace boiler $420,482 $9,456 $(-19,798.0)
(-464,256)
kWh
$(-2,748.0)
-
kW-mo/yr
$443,028
-
MMBtu
02 2.4222: Install adequate dryers on air lines to eliminate blowdown $15,055 $600 $13,720
321,700
kWh
$1,335
-
kW-mo/yr
-
03 2.2511: Insulate bare equipment $13,585 $2,910 $13,585
318,580
kWh
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $11,090 $1,200 $11,090
260,090
kWh
- -
05 2.2514: Cover open tanks $2,000 $3,900 $2,000
46,857
kWh
- -
06 2.7444: Close holes and openings in building such as broken windows $1,920 $54 $1,920
45,075
kWh
- -
07 2.7134: Use photocell controls $1,696 $225 $1,362
31,938
kWh
$334
-
kW-mo/yr
-
08 2.4314: Use synthetic lubricant $1,600 - $1,380
32,488
kWh
$220
-
kW-mo/yr
-
09 2.7135: Install occupancy sensors $1,032 $320 $1,032
24,200
kWh
- -
10 2.7122: Disconnect ballasts $510 $982 $450
10,562
kWh
$60
-
kW-mo/yr
-
11 2.7142: Utilize higher efficiency lamps and/or ballasts $254 $542 $230
5,396
kWh
$24
-
kW-mo/yr
-
TOTAL RECOMMENDED $469,224 $20,189 $26,971
632,630
kWh
$(-775.0)
-
kW-mo/yr
$443,028
-
MMBtu
TOTAL IMPLEMENTED $465,114 $15,307 $23,141
542,723
kWh
$(-1,055.0)
-
kW-mo/yr
$443,028
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs