Assessment Year 1999
Principal Product air-cooled and water-cooled chillers
NAICS
n/a
SIC 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment
Sales Range $100
M
to 500
M
# of Employees 900
Plant Area 420,000
ft2
Annual Production 7,500
pieces
Production Hrs. Annual 5,434
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $473,613 18,290,446
kWh
Electricity Demand $323,063 40,557
kW-mo/yr
Electricity Fees $3,192 -
Natural Gas $59,556 17,447
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $94,890 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $66,690

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Liquid (non-haz) Savings Administrative Changes Savings Increase in Production Savings
01 2.6218: Turn off equipment when not in use $16,960 - $16,960
663,247
kWh
- - - - -
02 2.7314: Reduce ventilation air $11,050 $12,600 - - $11,050
-
MMBtu
- - -
03 2.8121: Apply for tax-free status for energy purchases $7,900 $250 - - - - $7,900 -
04 2.3191: Use demand controller or load shedder $5,760 $2,000 - $5,760
-
kW-mo/yr
- - - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,660 $530 $1,450
54,807
kWh
$1,210
-
kW-mo/yr
- - - -
06 2.7442: Keep doors and windows shut when not on use $2,210 $1,000 $900
34,291
kWh
- $1,310
-
MMBtu
- - -
07 3.6124: Burn waste oil for heat $17,150 $10,500 $(-580.0)
(-22,567)
kWh
$(-310.0)
-
kW-mo/yr
$40
-
MMBtu
$18,000
-
gal
- -
08 4.621: Use fixtures to reduce machine changeout times $31,200 $8,000 - - - - - $31,200
TOTAL RECOMMENDED $94,890 $34,880 $18,730
729,778
kWh
$6,660
-
kW-mo/yr
$12,400
-
MMBtu
$18,000
-
gal
$7,900 $31,200
TOTAL IMPLEMENTED $66,690 $11,780 $19,310
752,345
kWh
$6,970
-
kW-mo/yr
$1,310
-
MMBtu
- $7,900 $31,200
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Liquid (non-haz) Savings Administrative Changes Savings Increase in Production Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs