Assessment Year 1994
Principal Product Commercial lawnmowers
NAICS
n/a
SIC 3523: Farm Machinery and Equipment
Sales Range $10
M
to 50
M
# of Employees 96
Plant Area 87,000
ft2
Annual Production 9,000
pieces
Production Hrs. Annual 2,184
hrs
Location (State) Nebraska

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $47,387 818,875
kWh
Natural Gas $36,128 9,280
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $17,571 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $8,108

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Personnel Changes Savings Primary Raw Material Savings
01 2.7145: Install skylights $7,072 $35,400 $7,072
122,216
kWh
- - -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $2,001 $8,058 $2,001
34,584
kWh
- - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,523 $4,449 $865
14,947
kWh
- $658 -
04 2.7135: Install occupancy sensors $390 $900 $390
6,741
kWh
- - -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $381 $360 $153
2,638
kWh
- $228 -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $179 $325 $102
1,758
kWh
- - $77
07 2.2437: Recover waste heat from equipment $2,066 $9,950 - $2,066
-
MMBtu
- -
08 2.2437: Recover waste heat from equipment $2,058 $2,075 - $2,058
-
MMBtu
- -
09 2.2437: Recover waste heat from equipment $1,195 $8,640 $(-594.0)
(-10,258)
kWh
$1,789
-
MMBtu
- -
10 2.7224: Reduce space conditioning during non-working hours $435 $400 $322
5,569
kWh
$113
-
MMBtu
- -
11 2.4231: Reduce the pressure of compressed air to the minimum required $271 $130 $271
4,689
kWh
- - -
TOTAL RECOMMENDED $17,571 $70,687 $10,582
182,884
kWh
$6,026
-
MMBtu
$886 $77
TOTAL IMPLEMENTED $8,108 $26,329 $1,119
19,343
kWh
$6,026
-
MMBtu
$886 $77
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Personnel Changes Savings Primary Raw Material Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs