ITAC Assessment: SU0596
ITAC logo
ITAC Assessment: SU0596
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2026
Principal Product Vinyl Windows
NAICS 326199: All Other Plastics Product Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $100
M
to 500
M
# of Employees 475
Plant Area 365,000
ft2
Annual Production 325,000
units
Production Hrs. Annual 4,200
hrs
Location (State) New Hampshire

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $668,242 5,125,000
kWh
Electricity Demand $241,901 12,360
kW-mo/yr
Electricity Fees $16,194 -
Natural Gas $150,210 15,063
MMBtu
Waste Disposal Costs
Water Usage $23,800 341,647
Tgal
TOTAL YEARLY COSTS $1,100,347
RECOMMENDED SAVINGS* $335,499 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Consumption Savings One-time Revenue or Avoided Cost Savings
01 3.1161: Eliminate/reduce an operation $5,355 $125 $2,486
19,125
kWh
$2,055
-
kW-mo/yr
$813
-
MMBtu
- -
02 2.6211: Conserve energy by efficient use of vending machines $2,112 $1,932 $2,112
16,250
kWh
- - - -
03 2.4322: Use or replace with energy efficient substitutes $2,976 $2,763 $1,720
13,228
kWh
$355
-
kW-mo/yr
- - $902
04 2.9114: Use solar heat to make electricty $15,954 $21,350 $15,954
122,724
kWh
- - - -
05 2.4221: Install compressor air intakes in coolest locations $343 $702 $343
2,642
kWh
- - - -
06 2.7447: Install vinyl strip / high speed / air curtain doors $1,475 $3,272 - - $1,475
-
MMBtu
- -
07 2.7447: Install vinyl strip / high speed / air curtain doors $252 $614 - - $252
-
MMBtu
- -
08 2.7232: Replace existing hvac unit with high efficiency model $20,297 $78,702 $1,399
10,760
kWh
- $18,898
-
MMBtu
- -
09 2.9114: Use solar heat to make electricty $279,051 $1,975,584 $279,051
2,146,548
kWh
- - - -
10 3.4151: Minimize water usage $7,684 $58,011 - - - $7,684
-
Tgal
-
TOTAL RECOMMENDED $335,499 $2,143,055 $303,066
2,331,277
kWh
$2,410
-
kW-mo/yr
$21,438
-
MMBtu
$7,684
-
Tgal
$902
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Consumption Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs