Assessment Year | 1997 |
---|---|
Principal Product | cranes, hoists, winches |
NAICS |
n/a
|
SIC | 3536: Overhead Traveling Cranes, Hoists, and Monorail Systems |
Sales Range | $5 M to 10M |
# of Employees | 60 |
Plant Area |
66,000
ft2
|
Annual Production | 5,000
pieces
|
Production Hrs. Annual | 4,394
hrs
|
Location (State) | Minnesota |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $18,897 | 579,719 |
kWh
|
$0.033 |
Electricity Demand | $21,147 | 2,820 |
kW-mo/yr
|
$7.50 |
Natural Gas | $19,436 | 4,425 |
MMBtu
|
$4.39 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,260 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,093 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (haz) Savings | Personnel Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4239: Eliminate or reduce compressed air usage | $2,822 | $1,825 |
$2,822
86,460
kWh
|
- | - | - | - | - | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,370 | $3,595 |
$760
23,447
kWh
|
$610
-
kW-mo/yr
|
- | - | - | - | - | - | |
03 | 2.7243: Improve air circulation with destratification fans / other methods | $2,349 | $3,850 |
$(-221.0)
(-6,741)
kWh
|
- |
$2,570
-
MMBtu
|
- | - | - | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $396 | $922 |
$243
7,327
kWh
|
$153
-
kW-mo/yr
|
- | - | - | - | - | - | |
05 | 2.7135: Install occupancy sensors | $448 | $266 |
$448
13,775
kWh
|
- | - | - | - | - | - | - | |
06 | 2.7261: Install timers and/or thermostats | $361 | $384 | - | - |
$361
-
MMBtu
|
- | - | - | - | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $140 | $170 |
$56
1,758
kWh
|
$84
-
kW-mo/yr
|
- | - | - | - | - | - | |
08 | 3.2121: Convert to electrostatic powder coating | $12,006 | $7,800 | - | - | - |
$1,206
-
gal
|
$3,373
-
lb
|
- | $7,427 | - | |
09 | 3.7198: Reduce / eliminate use of disposable product | $3,368 | $1,054 | - | - | - | - |
$2,161
-
lb
|
$1,053 | - | $154 | |
TOTAL RECOMMENDED | $23,260 | $19,866 |
$4,108
126,026
kWh
|
$847
-
kW-mo/yr
|
$2,931
-
MMBtu
|
$1,206
-
gal
|
$5,534
-
lb
|
$1,053 | $7,427 | $154 | ||
TOTAL IMPLEMENTED | $19,093 | $12,155 |
$3,121
95,545
kWh
|
$237
-
kW-mo/yr
|
$361
-
MMBtu
|
$1,206
-
gal
|
$5,534
-
lb
|
$1,053 | $7,427 | $154 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (haz) Savings | Personnel Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs