Assessment Year | 2025 |
---|---|
Principal Product | Hot dip galvanizing and steel coatings |
NAICS | 332812: Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers |
SIC | 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 74 |
Plant Area |
36,400
ft2
|
Annual Production | 40,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $39,265 | 965,900 |
kWh
|
$0.041 | |
Electricity Demand | $34,086 | 2,992 |
kW-mo/yr
|
$11.39 | |
Electricity Fees | $13,970 | - |
|
- | |
Natural Gas | $32,793 | 4,778 |
MMBtu
|
$6.86 | |
Waste Disposal Costs | |||||
Water Usage | $3,000 | 162 |
Tgal
|
$18.56 | |
TOTAL YEARLY COSTS | $123,113 | ||||
RECOMMENDED SAVINGS* | $8,252 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $4,564 | $96 | - | - | $4,564 | - | - | |
02 | 2.4239: Eliminate or reduce compressed air usage | $550 | - |
$550
13,426
kWh
|
- | - | - | - | |
03 | 2.2136: Install / repair insulation on steam lines | $516 | $372 | - | - | - |
$516
-
MMBtu
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,196 | $1,615 |
$430
10,494
kWh
|
$215
-
kW-mo/yr
|
- | - | $551 | |
05 | 2.4322: Use or replace with energy efficient substitutes | $355 | $612 |
$99
2,409
kWh
|
$38
-
kW-mo/yr
|
- | - | $218 | |
06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $247 | $451 | - | - | - |
$247
-
MMBtu
|
- | |
07 | 2.7447: Install vinyl strip / high speed / air curtain doors | $124 | $343 | - | - | - |
$124
-
MMBtu
|
- | |
08 | 2.2437: Recover waste heat from equipment | $151 | $424 | - | - | - |
$151
-
MMBtu
|
- | |
09 | 2.4221: Install compressor air intakes in coolest locations | $123 | $882 |
$123
2,997
kWh
|
- | - | - | - | |
10 | 2.7495: Install replacement doors | $310 | $2,745 | - | - | - |
$310
-
MMBtu
|
- | |
11 | 2.7135: Install occupancy sensors | $116 | $1,580 |
$116
2,821
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $8,252 | $9,120 |
$1,318
32,147
kWh
|
$253
-
kW-mo/yr
|
$4,564 |
$1,347
-
MMBtu
|
$769 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs