| Assessment Year | 2021 |
|---|---|
| Principal Product | Roll up shutter doors for emergency vehicles |
| NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $10 M to 50M |
| # of Employees | 45 |
| Plant Area |
31,800
ft2
|
| Annual Production | 5,000
units
|
| Production Hrs. Annual | 4,290
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $42,563 | 2,642,176 |
kWh
|
$0.016 |
| Electricity Demand | $51,275 | 7,807 |
kW-mo/yr
|
$6.57 |
| Electricity Fees | $283 | - |
|
- |
| Natural Gas | $87,006 | 16,567 |
MMBtu
|
$5.25 |
| TOTAL YEARLY COSTS | $181,127 | |||
| RECOMMENDED SAVINGS* | $10,309 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,299 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.8121: Apply for tax-free status for energy purchases | $5,573 | $66 | - | - | - | - | - | $5,573 | |
| 02 | 2.7441: Replace broken windows and/or window sash | $1,847 | $93 | - | - |
$1,847
-
MMBtu
|
- | - | - | |
| 03 | 2.7314: Reduce ventilation air | $592 | $499 |
$49
2,997
kWh
|
- |
$543
-
MMBtu
|
- | - | - | |
| 04 | 3.1161: Eliminate/reduce an operation | $1,845 | $2,386 |
$20
1,192
kWh
|
$512
-
kW-mo/yr
|
- | $23 | $1,290 | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $177 | $244 |
$42
2,628
kWh
|
$30
-
kW-mo/yr
|
- | $139 | $(-34.7) | - | |
| 06 | 2.4221: Install compressor air intakes in coolest locations | $275 | $402 |
$275
17,204
kWh
|
- | - | - | - | - | |
| TOTAL RECOMMENDED | $10,309 | $3,690 |
$386
24,021
kWh
|
$542
-
kW-mo/yr
|
$2,390
-
MMBtu
|
$162 | $1,255 | $5,573 | ||
| TOTAL IMPLEMENTED | $2,299 | $739 |
$317
19,832
kWh
|
$30
-
kW-mo/yr
|
$1,847
-
MMBtu
|
$139 | $(-34.7) | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings | |||