| Assessment Year | 2017 |
|---|---|
| Principal Product | Printed labels and flexible packaging |
| NAICS | 323111: Commercial Printing (except Screen and Books) |
| SIC | 2759: Commercial Printing, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 71 |
| Plant Area |
55,000
ft2
|
| Annual Production | 100,000
units
|
| Production Hrs. Annual | 4,498
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $114,456 | 1,292,861 |
kWh
|
$0.089 | |
| Electricity Demand | $58,173 | 5,631 |
kW-mo/yr
|
$10.33 | |
| Electricity Fees | $5,400 | - |
|
- | |
| Natural Gas | $9,646 | 1,508 |
MMBtu
|
$6.40 | |
| Waste Disposal Costs | |||||
| Water Usage | $1,000 | 2 |
Tgal
|
$437.06 | |
| TOTAL YEARLY COSTS | $188,675 | ||||
| RECOMMENDED SAVINGS* | $9,208 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $213 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,330 | - |
$1,330
14,945
kWh
|
- | - | |
| 02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $213 | $62 | - | - |
$213
-
MMBtu
|
|
| 03 | 2.7224: Reduce space conditioning during non-working hours | $437 | $191 | - | - |
$437
-
MMBtu
|
|
| 04 | 2.7314: Reduce ventilation air | $1,161 | $905 |
$302
3,386
kWh
|
- |
$859
-
MMBtu
|
|
| 05 | 2.4221: Install compressor air intakes in coolest locations | $995 | $820 |
$995
11,184
kWh
|
- | - | |
| 06 | 2.4322: Use or replace with energy efficient substitutes | $4,897 | $5,500 |
$1,736
19,508
kWh
|
$3,161
-
kW-mo/yr
|
- | |
| 07 | 2.6211: Conserve energy by efficient use of vending machines | $175 | $358 |
$175
1,971
kWh
|
- | - | |
| TOTAL RECOMMENDED | $9,208 | $7,836 |
$4,538
50,994
kWh
|
$3,161
-
kW-mo/yr
|
$1,509
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $213 | $62 | - | - |
$213
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs