| Assessment Year | 2016 |
|---|---|
| Principal Product | Millwork |
| NAICS | 321918: Other Millwork (including Flooring) |
| SIC | 2431: Millwork |
| Sales Range | $10 M to 50M |
| # of Employees | 55 |
| Plant Area |
30,000
ft2
|
| Annual Production | 16,000
pieces
|
| Production Hrs. Annual | 2,600
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $24,921 | 422,400 |
kWh
|
$0.059 |
| Electricity Demand | $17,046 | 1,725 |
kW-mo/yr
|
$9.88 |
| Electricity Fees | $4,615 | - |
|
- |
| Natural Gas | $1,711 | 299 |
MMBtu
|
$5.72 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,480 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,072 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.8121: Apply for tax-free status for energy purchases | $1,861 | - | - | - | - | $1,861 | |
| 02 | 2.7224: Reduce space conditioning during non-working hours | $609 | - | - | - |
$609
-
MMBtu
|
- | |
| 03 | 2.7122: Disconnect ballasts | $563 | - |
$318
5,382
kWh
|
$245
-
kW-mo/yr
|
- | - | |
| 04 | 3.1161: Eliminate/reduce an operation | $120 | - |
$97
1,644
kWh
|
$23
-
kW-mo/yr
|
- | - | |
| 05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $337 | $83 | - | - |
$337
-
MMBtu
|
- | |
| 06 | 2.6211: Conserve energy by efficient use of vending machines | $193 | $272 |
$193
3,274
kWh
|
- | - | - | |
| 07 | 2.7314: Reduce ventilation air | $513 | $822 |
$199
3,373
kWh
|
- |
$314
-
MMBtu
|
- | |
| 08 | 2.2437: Recover waste heat from equipment | $297 | $476 | - | - |
$297
-
MMBtu
|
- | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $168 | $336 |
$103
1,752
kWh
|
$24
-
kW-mo/yr
|
- | $41 | |
| 10 | 3.1161: Eliminate/reduce an operation | $607 | $1,364 | - | - | - | $607 | |
| 11 | 2.4221: Install compressor air intakes in coolest locations | $212 | $637 |
$212
3,588
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $5,480 | $3,990 |
$1,122
19,013
kWh
|
$292
-
kW-mo/yr
|
$1,557
-
MMBtu
|
$2,509 | ||
| TOTAL IMPLEMENTED | $4,072 | $2,531 |
$296
5,026
kWh
|
$24
-
kW-mo/yr
|
$1,243
-
MMBtu
|
$2,509 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs