| Assessment Year | 2015 |
|---|---|
| Principal Product | Heat Exchangers |
| NAICS | 332410: Power Boiler and Heat Exchanger Manufacturing |
| SIC | 3561: Pumps and Pumping Equipment |
| Sales Range | $50 M to 100M |
| # of Employees | 240 |
| Plant Area |
146,865
ft2
|
| Annual Production | 77,000,000
units
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $203,967 | 3,628,109 |
kWh
|
$0.056 |
| Electricity Demand | $41,012 | 10,764 |
kW-mo/yr
|
$3.81 |
| Electricity Fees | $15,124 | - |
|
- |
| Natural Gas | $54,762 | 10,924 |
MMBtu
|
$5.01 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $24,708 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $12,177 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Water Consumption Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4322: Use or replace with energy efficient substitutes | $288 | - |
$202
3,600
kWh
|
$86
-
kW-mo/yr
|
- | - | - | - | |
| 02 | 2.4314: Use synthetic lubricant | $1,074 | $200 |
$923
16,474
kWh
|
$151
-
kW-mo/yr
|
- | - | - | - | |
| 03 | 3.1161: Eliminate/reduce an operation | $11,567 | $5,737 |
$(-504.0)
(-9,000)
kWh
|
$(-274.0)
-
kW-mo/yr
|
- | $537 | - | $11,808 | |
| 04 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $6,133 | $4,684 |
$6,133
109,516
kWh
|
- | - | - | - | - | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $920 | $849 |
$920
16,427
kWh
|
- | - | - | - | - | |
| 06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,072 | $2,205 |
$(-245.0)
(-4,374)
kWh
|
$(-61.0)
-
kW-mo/yr
|
$1,378
-
MMBtu
|
- | - | - | |
| 07 | 2.6211: Conserve energy by efficient use of vending machines | $218 | $471 |
$218
3,895
kWh
|
- | - | - | - | - | |
| 08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $104 | $256 | - | - |
$104
-
MMBtu
|
- | - | - | |
| 09 | 3.4151: Minimize water usage | $3,332 | $15,700 | - | - | - | - |
$3,332
-
Tgal
|
- | |
| TOTAL RECOMMENDED | $24,708 | $30,102 |
$7,647
136,538
kWh
|
$(-98.0)
-
kW-mo/yr
|
$1,482
-
MMBtu
|
$537 |
$3,332
-
Tgal
|
$11,808 | ||
| TOTAL IMPLEMENTED | $12,177 | $6,464 |
$(-84.0)
(-1,505)
kWh
|
$(-188.0)
-
kW-mo/yr
|
$104
-
MMBtu
|
$537 | - | $11,808 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Water Consumption Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs