Assessment Year 2013
Principal Product Automotive VCT and Hvd Tensioners
NAICS 336350: Motor Vehicle Transmission and Power Train Parts Manufacturing
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $100
M
to 500
M
# of Employees 451
Plant Area 222,000
ft2
Annual Production 48,024,000
pieces
Production Hrs. Annual 7,488
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $889,319 17,361,643
kWh
Natural Gas $59,889 10,804
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $95,236 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $40,011

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 2.7144: Install spectral reflectors / delamp $4,610 - $4,610
90,035
kWh
- - -
02 2.4221: Install compressor air intakes in coolest locations $10,664 $994 $10,664
208,284
kWh
- - -
03 2.7444: Close holes and openings in building such as broken windows $1,064 $125 $133
2,602
kWh
$931
-
MMBtu
- -
04 2.7442: Keep doors and windows shut when not on use $18,079 $3,600 $2,265
44,238
kWh
$15,814
-
MMBtu
- -
05 2.7131: Add area lighting switches $429 $152 $429
8,386
kWh
- - -
06 2.7314: Reduce ventilation air $1,471 $882 $224
4,373
kWh
$1,247
-
MMBtu
- -
07 2.7135: Install occupancy sensors $2,294 $2,093 $2,294
44,808
kWh
- - -
08 2.7111: Reduce illumination to minimum necessary levels $35,885 $54,000 $35,885
700,877
kWh
- - -
09 3.1161: Eliminate/reduce an operation $13,535 $19,680 $(-86.0)
(-1,672)
kWh
- $2,100 $11,521
10 2.7442: Keep doors and windows shut when not on use $716 $1,567 $90
1,757
kWh
$626
-
MMBtu
- -
11 2.2414: Use waste heat from hot flue gases to preheat $6,108 $20,639 - $6,108
-
MMBtu
- -
12 2.6211: Conserve energy by efficient use of vending machines $381 $1,312 $381
7,433
kWh
- - -
TOTAL RECOMMENDED $95,236 $105,044 $56,889
1,111,121
kWh
$24,726
-
MMBtu
$2,100 $11,521
TOTAL IMPLEMENTED $40,011 $25,650 $9,645
188,397
kWh
$16,745
-
MMBtu
$2,100 $11,521
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings