| Assessment Year | 2013 |
|---|---|
| Principal Product | Corrugated Boxes |
| NAICS | 322211: Corrugated and Solid Fiber Box Manufacturing |
| SIC | 2653: Corrugated and Solid Fiber Boxes |
| Sales Range | $10 M to 50M |
| # of Employees | 65 |
| Plant Area |
85,000
ft2
|
| Annual Production | 216,000
thousand feet
|
| Production Hrs. Annual | 4,420
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $46,518 | 745,642 |
kWh
|
$0.062 |
| Electricity Demand | $37,036 | 2,947 |
kW-mo/yr
|
$12.57 |
| Electricity Fees | $9,815 | - |
|
- |
| Natural Gas | $14,225 | 1,640 |
MMBtu
|
$8.67 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,983 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,904 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $814 | - |
$525
8,398
kWh
|
$289
-
kW-mo/yr
|
- | - | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $799 | - |
$799
12,790
kWh
|
- | - | - | |
| 03 | 2.4322: Use or replace with energy efficient substitutes | $648 | - |
$195
3,120
kWh
|
$453
-
kW-mo/yr
|
- | - | |
| 04 | 2.7224: Reduce space conditioning during non-working hours | $555 | $139 | - | - |
$555
-
MMBtu
|
- | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $831 | $307 |
$831
13,302
kWh
|
- | - | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $464 | $170 |
$464
7,420
kWh
|
- | - | - | |
| 07 | 2.2136: Install / repair insulation on steam lines | $212 | $393 | - | - |
$212
-
MMBtu
|
- | |
| 08 | 2.6211: Conserve energy by efficient use of vending machines | $150 | $414 |
$150
2,397
kWh
|
- | - | - | |
| 09 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,115 | $8,297 |
$(-303.0)
(-4,713)
kWh
|
$(-226.0)
-
kW-mo/yr
|
$2,644
-
MMBtu
|
- | |
| 10 | 2.1224: Replace boiler | $945 | $4,440 | - | - |
$945
-
MMBtu
|
- | |
| 11 | 4.821: Pay bills on time to avoid late fees | $450 | - | - | - | - | $450 | |
| TOTAL RECOMMENDED | $7,983 | $14,160 |
$2,661
42,714
kWh
|
$516
-
kW-mo/yr
|
$4,356
-
MMBtu
|
$450 | ||
| TOTAL IMPLEMENTED | $4,904 | $5,449 |
$2,289
36,632
kWh
|
$453
-
kW-mo/yr
|
$1,712
-
MMBtu
|
$450 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs