Assessment Year 2010
Principal Product Compressed Air Tools
NAICS 333991: Power-Driven Handtool Manufacturing
SIC 3546: Power-Driven Handtools
Sales Range $100
M
to 500
M
# of Employees 140
Plant Area 420,000
ft2
Annual Production 6,000,000
pieces
Production Hrs. Annual 4,420
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $413,468 8,738,028
kWh
Electricity Demand $128,064 19,612
kW-mo/yr
Electricity Fees $16,825 -
Natural Gas $419,994 34,662
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $64,187 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 2.4111: Utilize energy-efficient belts and other improved mechanisms $17,252 - $12,527
266,526
kWh
$4,725
-
kW-mo/yr
- -
02 2.6231: Utilize controls to operate equipment only when needed $3,692 - $3,692
78,551
kWh
- - -
03 2.4314: Use synthetic lubricant $3,669 - $2,663
56,664
kWh
$1,006
-
kW-mo/yr
- -
04 2.4231: Reduce the pressure of compressed air to the minimum required $2,942 - $2,171
46,192
kWh
$771
-
kW-mo/yr
- -
05 4.821: Pay bills on time to avoid late fees $2,435 - - - - $2,435
06 2.4221: Install compressor air intakes in coolest locations $3,028 - $1,766
37,580
kWh
$1,262
-
kW-mo/yr
- -
07 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,954 - $2,178
46,332
kWh
$776
-
kW-mo/yr
- -
08 2.7135: Install occupancy sensors $270 $291 $270
5,737
kWh
- - -
09 2.6211: Conserve energy by efficient use of vending machines $337 $898 $337
7,175
kWh
- - -
10 2.7142: Utilize higher efficiency lamps and/or ballasts $609 $2,721 $438
9,282
kWh
$171
-
kW-mo/yr
- -
11 2.1311: Replace electrically-operated equipment with fossil fuel equipment $24,796 $150,000 $49,858
1,060,800
kWh
$18,806
-
kW-mo/yr
$(-43,868.0)
-
MMBtu
-
12 2.4321: Upgrade obsolete equipment $2,203 $19,090 $1,600
34,034
kWh
$603
-
kW-mo/yr
- -
TOTAL RECOMMENDED $64,187 $173,000 $77,500
1,648,873
kWh
$28,120
-
kW-mo/yr
$(-43,868.0)
-
MMBtu
$2,435
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings