Assessment Year | 2008 |
---|---|
Principal Product | Wooden Shipping Boxes |
NAICS | 322211: Corrugated and Solid Fiber Box Manufacturing |
SIC | 2449: Wood Containers, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 119 |
Plant Area |
90,000
ft2
|
Annual Production | 2,300,000
pieces
|
Production Hrs. Annual | 4,394
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $74,279 | 691,654 |
kWh
|
$0.11 |
Electricity Demand | $43,011 | 2,478 |
kW-mo/yr
|
$17.36 |
Electricity Fees | $3,786 | - |
|
- |
Natural Gas | $39,351 | 3,647 |
MMBtu
|
$10.79 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $174,468 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $173,184 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.6231: Utilize controls to operate equipment only when needed | $2,198 | - |
$2,198
20,544
kWh
|
- | - | - | |
02 | 2.4314: Use synthetic lubricant | $913 | - |
$635
5,932
kWh
|
$278
-
kW-mo/yr
|
- | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $527 | - |
$371
3,471
kWh
|
$156
-
kW-mo/yr
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,164 | $198 |
$1,505
14,061
kWh
|
$659
-
kW-mo/yr
|
- | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $1,485 | $209 |
$1,034
9,667
kWh
|
$451
-
kW-mo/yr
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,570 | $333 |
$1,097
10,249
kWh
|
$243
-
kW-mo/yr
|
$142 | $88 | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,786 | $2,539 |
$2,624
24,519
kWh
|
$1,162
-
kW-mo/yr
|
- | - | |
08 | 3.1182: Make a new by-product | $161,000 | $171,101 | - | - | - | $161,000 | |
09 | 2.6211: Conserve energy by efficient use of vending machines | $220 | $268 |
$220
2,059
kWh
|
- | - | - | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $454 | $718 |
$315
2,944
kWh
|
$139
-
kW-mo/yr
|
- | - | |
11 | 2.7135: Install occupancy sensors | $151 | $366 |
$151
1,407
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $174,468 | $175,732 |
$10,150
94,853
kWh
|
$3,088
-
kW-mo/yr
|
$142 | $161,088 | ||
TOTAL IMPLEMENTED | $173,184 | $175,098 |
$9,144
85,455
kWh
|
$2,810
-
kW-mo/yr
|
$142 | $161,088 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs