Assessment Year | 2008 |
---|---|
Principal Product | Wire, Ribbon, Foil, Preforms |
NAICS | 331491: Nonferrous Metal (except Copper and Aluminum) Rolling, Drawing, and Extruding |
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 106 |
Plant Area |
26,269
ft2
|
Annual Production | 79,000,000
pieces
|
Production Hrs. Annual | 8,215
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $141,625 | 1,599,554 |
kWh
|
$0.089 |
Electricity Demand | $52,768 | 4,522 |
kW-mo/yr
|
$11.67 |
Electricity Fees | $16,325 | - |
|
- |
Natural Gas | $86,936 | 83,915 |
MMBtu
|
$1.04 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $173,853 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,215 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.6231: Utilize controls to operate equipment only when needed | $6,391 | - |
$6,391
71,808
kWh
|
- | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,817 | - |
$3,163
35,530
kWh
|
$654
-
kW-mo/yr
|
- | |
03 | 2.4322: Use or replace with energy efficient substitutes | $1,166 | - |
$641
7,200
kWh
|
$525
-
kW-mo/yr
|
- | |
04 | 3.1191: Change procedures / equipment / operating conditions | $151,996 | $23,800 |
$(-1,388.0)
(-15,600)
kWh
|
$(-350.0)
-
kW-mo/yr
|
$153,734 | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,953 | $339 |
$1,638
18,402
kWh
|
$315
-
kW-mo/yr
|
- | |
06 | 2.4221: Install compressor air intakes in coolest locations | $1,096 | $424 |
$921
10,351
kWh
|
$175
-
kW-mo/yr
|
- | |
07 | 2.6211: Conserve energy by efficient use of vending machines | $114 | $65 |
$114
1,286
kWh
|
- | - | |
08 | 2.4322: Use or replace with energy efficient substitutes | $7,220 | $40,650 |
$6,100
68,544
kWh
|
$1,120
-
kW-mo/yr
|
- | |
09 | 2.7135: Install occupancy sensors | $100 | $626 |
$100
1,123
kWh
|
- | - | |
TOTAL RECOMMENDED | $173,853 | $65,904 |
$17,680
198,644
kWh
|
$2,439
-
kW-mo/yr
|
$153,734 | ||
TOTAL IMPLEMENTED | $4,215 | $763 |
$3,200
35,953
kWh
|
$1,015
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs