ITAC Assessment: SU0137
ITAC logo
ITAC Assessment: SU0137
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2002
Principal Product #9 and #10 envelopes
NAICS
n/a
SIC 2677: Envelopes
Sales Range $10
M
to 50
M
# of Employees 95
Plant Area 88,000
ft2
Annual Production 1,040,000,000
units
Production Hrs. Annual 6,240
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $175,934 2,714,100
kWh
Electricity Demand $61,416 6,252
kW-mo/yr
Natural Gas $15,424 1,342
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $23,840 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $18,799

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.4111: Utilize energy-efficient belts and other improved mechanisms $111 - $111
1,810
kWh
- - -
02 2.7124: Make a practice of turning off lights when not needed $429 $71 $414
6,895
kWh
$15
-
kW-mo/yr
- -
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $806 $2,150 $806
13,418
kWh
- - -
04 2.3212: Optimize plant power factor $923 $3,750 - - $923 -
05 2.4221: Install compressor air intakes in coolest locations $1,228 $327 $1,228
20,465
kWh
- - -
06 2.2531: Re-size charging openings or add movable cover or door $3,312 $327 - - - $3,312
-
MMBtu
07 2.4231: Reduce the pressure of compressed air to the minimum required $4,451 - $4,451
74,180
kWh
- - -
08 2.6231: Utilize controls to operate equipment only when needed $12,580 $510 $12,580
262,080
kWh
- - -
TOTAL RECOMMENDED $23,840 $7,135 $19,590
378,848
kWh
$15
-
kW-mo/yr
$923 $3,312
-
MMBtu
TOTAL IMPLEMENTED $18,799 $908 $18,784
365,430
kWh
$15
-
kW-mo/yr
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs