Assessment Year | 1993 |
---|---|
Principal Product | Lumber |
NAICS |
n/a
|
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $10 M to 50M |
# of Employees | 34 |
Plant Area |
n/a
|
Annual Production | 38,900,000
thousand feet
|
Production Hrs. Annual | 4,320
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $136,129 | 2,776,378 |
kWh
|
$0.049 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $26,638 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $21,780 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $17,105 | $10,000 |
$17,105
413,834
kWh
|
|
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,858 | $5,000 |
$4,858
116,354
kWh
|
|
03 | 2.3212: Optimize plant power factor | $3,535 | $7,500 |
$3,535
-
kWh
|
|
04 | 2.4133: Use most efficient type of electric motors | $352 | $1,320 |
$352
7,620
kWh
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $788 | - |
$788
16,413
kWh
|
|
TOTAL RECOMMENDED | $26,638 | $23,820 |
$26,638
554,221
kWh
|
||
TOTAL IMPLEMENTED | $21,780 | $18,820 |
$21,780
437,867
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs