Assessment Year | 2001 |
---|---|
Principal Product | packaging machinery |
NAICS |
n/a
|
SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 180 |
Plant Area |
77,500
ft2
|
Annual Production | 100
pieces
|
Production Hrs. Annual | 4,940
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $39,307 | 722,240 |
kWh
|
$0.054 |
Electricity Demand | $28,694 | 2,376 |
kW-mo/yr
|
$12.08 |
Electricity Fees | $9,657 | - |
|
- |
Natural Gas | $24,368 | 1,695 |
MMBtu
|
$14.38 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,116 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,599 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 4.452: Eliminate shift | $13,517 | - |
$11,403
207,740
kWh
|
- |
$2,114
-
MMBtu
|
- | - | |
02 | 2.2437: Recover waste heat from equipment | $2,968 | $694 | - | - |
$2,968
-
MMBtu
|
- | - | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $2,325 | $7,060 |
$1,287
32,169
kWh
|
$1,038
-
kW-mo/yr
|
- | - | - | |
04 | 2.8118: Check for accuracy of utility / power meters | $1,800 | - | - | - | - | $1,200 | $600 | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $739 | - | - | - |
$739
-
MMBtu
|
- | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $378 | $196 |
$378
7,191
kWh
|
- | - | - | - | |
07 | 2.2511: Insulate bare equipment | $347 | $117 |
$347
8,678
kWh
|
- | - | - | - | |
08 | 2.7444: Close holes and openings in building such as broken windows | $42 | $3 | - | - |
$42
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $22,116 | $8,070 |
$13,415
255,778
kWh
|
$1,038
-
kW-mo/yr
|
$5,863
-
MMBtu
|
$1,200 | $600 | ||
TOTAL IMPLEMENTED | $8,599 | $8,070 |
$2,012
48,038
kWh
|
$1,038
-
kW-mo/yr
|
$3,749
-
MMBtu
|
$1,200 | $600 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs