Assessment Year 1985
Principal Product COMMUNICATION CABLES
NAICS
n/a
SIC 3357: Drawing and Insulating of Nonferrous Wire
Sales Range $5
M
to 10
M
# of Employees 100
Plant Area
n/a
Annual Production 800,000
pieces
Production Hrs. Annual 6,000
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $171,489 1,830,891
kWh
Natural Gas $23,673 4,022
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $73,819 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $11,676

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $5,504 $858 $5,504
58,910
kWh
-
02 2.4321: Upgrade obsolete equipment $43,200 $19,000 $43,200
461,313
kWh
-
03 2.4221: Install compressor air intakes in coolest locations $502 $300 $502
5,275
kWh
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,210 $64 $1,210
12,896
kWh
-
05 2.6212: Turn off equipment during breaks, reduce operating time $266 - $266
2,931
kWh
-
06 2.4239: Eliminate or reduce compressed air usage $6,243 $1,200 $6,243
66,823
kWh
-
07 2.1311: Replace electrically-operated equipment with fossil fuel equipment $275 $410 $338
3,517
kWh
$(-63.0)
-
MMBtu
08 2.1311: Replace electrically-operated equipment with fossil fuel equipment $3,124 $2,000 $3,480
36,928
kWh
$(-356.0)
-
MMBtu
09 2.7224: Reduce space conditioning during non-working hours $4,039 - - $4,039
-
MMBtu
10 2.2437: Recover waste heat from equipment $6,363 $7,500 - $6,363
-
MMBtu
11 2.1123: Install automatic stack damper $331 $400 - $331
-
MMBtu
12 2.7441: Replace broken windows and/or window sash $2,762 $884 - $2,762
-
MMBtu
TOTAL RECOMMENDED $73,819 $32,616 $60,743
648,593
kWh
$13,076
-
MMBtu
TOTAL IMPLEMENTED $11,676 $3,358 $5,294
56,272
kWh
$6,382
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs