Assessment Year | 2018 |
---|---|
Principal Product | Packaged cooking oils and shortenings |
NAICS | 311224: Soybean and Other Oilseed Processing |
SIC | 2099: Food Preparations, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
375,000
ft2
|
Annual Production | 375,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $148,442 | 962,538 |
kWh
|
$0.15 |
Electricity Demand | $57,179 | 6,552 |
kW-mo/yr
|
$8.73 |
Natural Gas | $152,494 | 20,902 |
MMBtu
|
$7.30 |
TOTAL YEARLY COSTS | $358,114 | |||
RECOMMENDED SAVINGS* | $185,606 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $88,382 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $6,177 | $2,407 |
$6,177
61,716
kWh
|
- | - | - | - | - | |
02 | 2.4224: Upgrade controls on compressors | $13,070 | $22,633 |
$13,070
130,596
kWh
|
- | - | - | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $47,808 | $97,552 |
$32,765
327,385
kWh
|
$13,821
-
kW-mo/yr
|
- | $1,819 | - | $(-597.0) | |
04 | 2.1231: Establish burner maintenance schedule for boilers | $5,255 | $11,220 | - | - |
$5,255
-
MMBtu
|
- | - | - | |
05 | 2.2122: Install / repair insulation on condensate lines | $1,743 | $4,357 | - | - |
$1,743
-
MMBtu
|
- | - | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $209 | $564 |
$142
1,418
kWh
|
$67
-
kW-mo/yr
|
- | - | - | - | |
07 | 2.2621: Modify refrigeration system to operate at a lower pressure | $14,120 | $58,070 |
$14,120
141,084
kWh
|
- | - | - | - | - | |
08 | 2.9114: Use solar heat to make electricty | $97,224 | $532,260 |
$71,492
714,351
kWh
|
$24,127
-
kW-mo/yr
|
- | - | $1,605 | - | |
TOTAL RECOMMENDED | $185,606 | $729,063 |
$137,766
1,376,550
kWh
|
$38,015
-
kW-mo/yr
|
$6,998
-
MMBtu
|
$1,819 | $1,605 | $(-597.0) | ||
TOTAL IMPLEMENTED | $88,382 | $196,803 |
$66,274
662,199
kWh
|
$13,888
-
kW-mo/yr
|
$6,998
-
MMBtu
|
$1,819 | - | $(-597.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs