Assessment Year | 2008 |
---|---|
Principal Product | Various Food and Baked Goods |
NAICS | 311999: All Other Miscellaneous Food Manufacturing |
SIC | 2015: Poultry Slaughtering and Processing |
Sales Range | $5 M to 10M |
# of Employees | 300 |
Plant Area |
47,056
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Hawaii |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $614,257 | 4,091,600 |
kWh
|
$0.15 |
Electricity Demand | $87,301 | 8,776 |
kW-mo/yr
|
$9.95 |
Electricity Fees | $37,339 | - |
|
- |
LPG | $11,926 | 929 |
MMBtu
|
$12.84 |
Fuel Oil #1 | $299,084 | 14,849 |
MMBtu
|
$20.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $231,511 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $193,288 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #1 Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,446 | - |
$1,881
9,386
kWh
|
$565
-
kW-mo/yr
|
- | - | |
02 | 2.7212: Install or upgrade insulation on hvac distribution systems | $4,812 | $1,046 |
$4,812
24,007
kWh
|
- | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $1,974 | $913 |
$1,712
8,540
kWh
|
$262
-
kW-mo/yr
|
- | - | |
04 | 2.6231: Utilize controls to operate equipment only when needed | $1,655 | $798 |
$1,655
8,257
kWh
|
- | - | - | |
05 | 2.7135: Install occupancy sensors | $4,350 | $2,680 |
$4,350
21,705
kWh
|
- | - | - | |
06 | 2.1331: Burn a less expensive grade of fuel | $85,730 | $61,250 | - | - | - | $85,730 | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $13,557 | $10,440 |
$13,557
67,637
kWh
|
- | - | - | |
08 | 2.2414: Use waste heat from hot flue gases to preheat | $20,316 | $22,812 | - | - |
$20,316
-
MMBtu
|
- | |
09 | 2.7212: Install or upgrade insulation on hvac distribution systems | $9,060 | $11,740 |
$9,060
45,201
kWh
|
- | - | - | |
10 | 2.1241: Reduce excessive boiler blowdown | $6,734 | $8,900 | - | - |
$6,734
-
MMBtu
|
- | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $409 | $801 |
$373
19,020
kWh
|
$36
-
kW-mo/yr
|
- | - | |
12 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,909 | $2,854 |
$1,739
8,678
kWh
|
$170
-
kW-mo/yr
|
- | - | |
13 | 2.4239: Eliminate or reduce compressed air usage | $2,296 | $2,489 |
$1,601
7,987
kWh
|
$695
-
kW-mo/yr
|
- | - | |
14 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $63,306 | $125,074 |
$48,931
244,119
kWh
|
$14,375
-
kW-mo/yr
|
- | - | |
15 | 2.4226: Use / purchase optimum sized compressor | $6,376 | $28,462 |
$6,376
31,810
kWh
|
- | - | - | |
16 | 2.7232: Replace existing hvac unit with high efficiency model | $6,581 | $35,138 |
$4,844
24,167
kWh
|
$1,737
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $231,511 | $315,397 |
$100,891
520,514
kWh
|
$17,840
-
kW-mo/yr
|
$27,050
-
MMBtu
|
$85,730 | ||
TOTAL IMPLEMENTED | $193,288 | $279,465 |
$82,984
431,172
kWh
|
$17,840
-
kW-mo/yr
|
$6,734
-
MMBtu
|
$85,730 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #1 Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs