| Assessment Year | 2026 |
|---|---|
| Principal Product | Metal Forgings |
| NAICS | 332111: Iron and Steel Forging |
| SIC | 3462: Iron and Steel Forgings |
| Sales Range | $50 M to 100M |
| # of Employees | 105 |
| Plant Area |
90,000
ft2
|
| Annual Production | 225
units
|
| Production Hrs. Annual | 4,250
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $126,300 | 7,846,542 |
kWh
|
$0.016 |
| Electricity Demand | $1,022,007 | 15,744 |
kW-mo/yr
|
$64.91 |
| Electricity Fees | $15,053 | - |
|
- |
| Natural Gas | $174,893 | 12,605 |
MMBtu
|
$13.87 |
| TOTAL YEARLY COSTS | $1,338,253 | |||
| RECOMMENDED SAVINGS* | $2,288,922 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $605,975 | $1,453,756 |
$34,076
2,116,520
kWh
|
$571,899
-
kW-mo/yr
|
- | |
| 02 | 2.3141: Use battery storage for demand control | $1,255,541 | $298,093 |
$(-2,415.0)
(-150,000)
kWh
|
$1,257,956
-
kW-mo/yr
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $84 | $424 |
$12
774
kWh
|
$72
-
kW-mo/yr
|
- | |
| 04 | 2.4223: Install direct acting units in place of compressed air pressure system in safety system | $918 | $8,600 |
$918
56,999
kWh
|
- | - | |
| 05 | 2.4133: Use most efficient type of electric motors | $3,266 | $34,026 |
$202
12,538
kWh
|
$3,064
-
kW-mo/yr
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,018 | $2,153 |
$488
30,326
kWh
|
$7,530
-
kW-mo/yr
|
- | |
| 07 | 2.2414: Use waste heat from hot flue gases to preheat | $1,956 | $1,671 | - | - |
$1,956
-
MMBtu
|
|
| 08 | 2.1121: Use insulation in furnaces to facilitate heating / cooling | $83,314 | $23,101 |
$12,743
791,521
kWh
|
$70,570
-
kW-mo/yr
|
- | |
| 09 | 2.1221: Replace obsolete burners with more efficient ones | $155,489 | - | - | - |
$155,489
-
MMBtu
|
|
| 10 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $174,361 | $805,450 |
$38,259
2,376,353
kWh
|
$136,102
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $2,288,922 | $2,627,273 |
$84,284
5,235,031
kWh
|
$2,047,192
-
kW-mo/yr
|
$157,446
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs