| Assessment Year | 2017 |
|---|---|
| Principal Product | plastic bottles |
| NAICS | 326160: Plastics Bottle Manufacturing |
| SIC | 3085: Plastics Bottles |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
60,000
ft2
|
| Annual Production | 21,000,000
pieces
|
| Production Hrs. Annual | 2,184
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $1,114,523 | 15,602,700 |
kWh
|
$0.071 | |
| Natural Gas | $13,293 | 1,535 |
MMBtu
|
$8.66 | |
| Waste Disposal Costs | |||||
| Water Usage | $1,411 | 676,200 |
Tgal
|
$0.002 | |
| TOTAL YEARLY COSTS | $1,129,228 | ||||
| RECOMMENDED SAVINGS* | $13,048 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,640 | $350 |
$5,640
79,442
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,041 | $34,350 |
$3,355
47,250
kWh
|
$2,686 | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $762 | $1,222 |
$248
3,498
kWh
|
$513 | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $605 | - |
$605
8,518
kWh
|
- | |
| TOTAL RECOMMENDED | $13,048 | $35,922 |
$9,848
138,708
kWh
|
$3,199 | ||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs