Assessment Year 2024
Principal Product Plastic Injection Molded Parts
NAICS 326121: Unlaminated Plastics Profile Shape Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $1
M
to 5
M
# of Employees 48
Plant Area 28,000
ft2
Annual Production 10,000,000
pieces
Production Hrs. Annual 6,000
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $88,004 456,931
kWh
Electricity Demand $31,644 1,745
kW-mo/yr
Electricity Fees $2,243 -
TOTAL YEARLY COSTS $121,891
RECOMMENDED SAVINGS* $98,427 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings
01 2.4221: Install compressor air intakes in coolest locations $11,382 $8,850 $10,403
54,000
kWh
$979
-
kW-mo/yr
-
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,218 $7,799 $4,218
21,901
kWh
- -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $5,849 $5,725 $4,793
24,885
kWh
$990
-
kW-mo/yr
$66
04 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $2,987 $2,109 $2,354
12,220
kWh
$633
-
kW-mo/yr
-
05 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $23,570 $42,732 $17,123
88,902
kWh
$6,447
-
kW-mo/yr
-
06 2.6231: Utilize controls to operate equipment only when needed $47,700 $5,600 $34,659
179,955
kWh
$13,041
-
kW-mo/yr
-
07 2.7228: Avoid introducing hot, humid, or dirty air into hvac system $2,721 $5,005 $2,187
11,353
kWh
$534
-
kW-mo/yr
-
TOTAL RECOMMENDED $98,427 $77,820 $75,737
393,216
kWh
$22,624
-
kW-mo/yr
$66
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs