Assessment Year | 2013 |
---|---|
Principal Product | APET containers |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 175 |
Plant Area |
74,000
ft2
|
Annual Production | 10,000,000
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,620,157 | 21,415,842 |
kWh
|
$0.076 |
Electricity Demand | $603,240 | 39,770 |
kW-mo/yr
|
$15.17 |
Natural Gas | $74,013 | 14,837 |
MMBtu
|
$4.99 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $774,533 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $30,141 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 3.1192: Reduce scrap production | $478,006 | $153,240 |
$356,659
4,711,485
kWh
|
$102,105
-
kW-mo/yr
|
$19,242
-
MMBtu
|
|
02 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $74,589 | $105,000 |
$74,589
985,324
kWh
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $72,583 | $20,000 |
$56,428
745,416
kWh
|
$16,155
-
kW-mo/yr
|
- | |
04 | 2.2511: Insulate bare equipment | $38,801 | $8,131 |
$35,791
472,804
kWh
|
$3,010
-
kW-mo/yr
|
- | |
05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $32,247 | $22,575 |
$34,458
455,191
kWh
|
$7,473
-
kW-mo/yr
|
$(-9,684.0)
-
MMBtu
|
|
06 | 3.1191: Change procedures / equipment / operating conditions | $31,432 | $18,685 |
$20,392
269,382
kWh
|
$5,414
-
kW-mo/yr
|
$5,626
-
MMBtu
|
|
07 | 2.3137: Use power during off-peak periods | $14,075 | $28,900 | - |
$14,075
-
kW-mo/yr
|
- | |
08 | 2.2414: Use waste heat from hot flue gases to preheat | $13,799 | $24,000 | - | - |
$13,799
-
MMBtu
|
|
09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $12,883 | $30,800 |
$12,883
170,184
kWh
|
- | - | |
10 | 2.7134: Use photocell controls | $3,183 | $3,515 |
$2,784
36,789
kWh
|
$399
-
kW-mo/yr
|
- | |
11 | 2.6231: Utilize controls to operate equipment only when needed | $1,517 | $4,185 |
$1,224
16,174
kWh
|
$293
-
kW-mo/yr
|
- | |
12 | 2.7261: Install timers and/or thermostats | $1,418 | $1,750 |
$1,418
18,743
kWh
|
- | - | |
TOTAL RECOMMENDED | $774,533 | $420,781 |
$596,626
7,881,492
kWh
|
$148,924
-
kW-mo/yr
|
$28,983
-
MMBtu
|
||
TOTAL IMPLEMENTED | $30,141 | $63,215 |
$15,667
206,973
kWh
|
$14,474
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs