ITAC Assessment: SD0326
ITAC logo
ITAC Assessment: SD0326
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2003
Principal Product Steel pipes
NAICS 332312: Fabricated Structural Metal Manufacturing
SIC 3443: Fabricated Plate Work (Boiler Shops)
Sales Range $1
M
to 5
M
# of Employees 35
Plant Area 3,092,760
ft2
Annual Production 700
ton
Production Hrs. Annual 2,338
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $160,951 1,438,111
kWh
Electricity Demand $50,262 3,600
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $130,354 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $35,397

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4226: Use / purchase optimum sized compressor $44,623 - $26,354
235,089
kWh
$18,269
-
kW-mo/yr
-
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $35,397 $4,000 $35,397
315,759
kWh
- -
03 2.1311: Replace electrically-operated equipment with fossil fuel equipment $15,861 $20,000 $9,173
81,830
kWh
$8,550
-
kW-mo/yr
$(-1,862.0)
-
MMBtu
04 2.4324: Replace hydraulic / pneumatic equipment with electric equipment $14,893 $7,700 $14,893
148,928
kWh
- -
05 2.7111: Reduce illumination to minimum necessary levels $7,795 $384 $4,717
42,075
kWh
$3,078
-
kW-mo/yr
-
06 2.4226: Use / purchase optimum sized compressor $4,905 $7,000 $2,896
25,836
kWh
$2,009
-
kW-mo/yr
-
07 2.7134: Use photocell controls $4,846 $6,000 $2,594
23,140
kWh
$2,252
-
kW-mo/yr
-
08 2.7261: Install timers and/or thermostats $2,034 $500 $2,034
18,144
kWh
- -
TOTAL RECOMMENDED $130,354 $45,584 $98,058
890,801
kWh
$34,158
-
kW-mo/yr
$(-1,862.0)
-
MMBtu
TOTAL IMPLEMENTED $35,397 $4,000 $35,397
315,759
kWh
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs