Assessment Year | 1998 |
---|---|
Principal Product | Die Castings |
NAICS |
n/a
|
SIC | 3463: Nonferrous Forgings |
Sales Range | $10 M to 50M |
# of Employees | 115 |
Plant Area |
100,000
ft2
|
Annual Production | 380,000
pieces
|
Production Hrs. Annual | 4,726
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $97,261 | 1,927,608 |
kWh
|
$0.050 |
Electricity Demand | $71,567 | 7,535 |
kW-mo/yr
|
$9.50 |
Natural Gas | $87,867 | 19,776 |
MMBtu
|
$4.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $347,550 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $39,806 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $7,869 | $11,580 |
$5,436
108,734
kWh
|
$2,433
-
kW-mo/yr
|
- | - | |
02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $30,174 | $15,667 |
$24,816
496,483
kWh
|
$5,358
-
kW-mo/yr
|
- | - | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $30,878 | $116,225 |
$20,162
403,283
kWh
|
$10,716
-
kW-mo/yr
|
- | - | |
04 | 2.2425: Use flue gases to heat process or service water | $17,334 | $8,125 |
$14,256
285,170
kWh
|
$3,078
-
kW-mo/yr
|
- | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,620 | $1,350 |
$6,407
128,077
kWh
|
$2,213
-
kW-mo/yr
|
- | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,072 | - |
$3,027
60,668
kWh
|
$1,045
-
kW-mo/yr
|
- | - | |
07 | 2.7261: Install timers and/or thermostats | $788 | $300 |
$788
15,533
kWh
|
- | - | - | |
08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,086 | $4,856 |
$1,127
22,567
kWh
|
$959
-
kW-mo/yr
|
- | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,443 | $6,942 |
$5,532
110,785
kWh
|
$1,911
-
kW-mo/yr
|
- | - | |
10 | 2.7144: Install spectral reflectors / delamp | $2,302 | $2,150 |
$1,606
32,239
kWh
|
$696
-
kW-mo/yr
|
- | - | |
11 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $9,500 | $9,000 | - | - | - | $9,500 | |
12 | 3.5131: Recycle white water | $445 | - | - | - |
$445
-
gal
|
- | |
13 | 4.421: Modify current incentive program | $226,039 | $560,000 | - | - | - | $226,039 | |
TOTAL RECOMMENDED | $347,550 | $736,195 |
$83,157
1,663,539
kWh
|
$28,409
-
kW-mo/yr
|
$445
-
gal
|
$235,539 | ||
TOTAL IMPLEMENTED | $39,806 | $31,022 |
$22,008
440,503
kWh
|
$8,298
-
kW-mo/yr
|
- | $9,500 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs