Assessment Year 1993
Principal Product PUNCH AND SALAD DRESSING
NAICS
n/a
SIC 2087: Flavoring Extracts and Flavoring Syrups, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 70
Plant Area
n/a
Annual Production 1,000,000
pieces
Production Hrs. Annual 6,248
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $36,510 280,481
kWh
Natural Gas $11,537 1,945
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $8,252 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $7,796

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.4133: Use most efficient type of electric motors $110 $142 $110
879
kWh
- -
02 2.4231: Reduce the pressure of compressed air to the minimum required $263 $20 $263
2,052
kWh
- -
03 2.2136: Install / repair insulation on steam lines $217 $117 - $217
-
MMBtu
-
04 2.2122: Install / repair insulation on condensate lines $193 $108 - $193
-
MMBtu
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $1,432 - $1,502
11,430
kWh
- $(-70.0)
06 2.7144: Install spectral reflectors / delamp $3,237 $2,680 $3,207
24,619
kWh
- $30
07 2.6232: Install set-back timers $1,003 $1,160 $913
7,034
kWh
- $90
08 2.7134: Use photocell controls $650 $345 $615
4,689
kWh
- $35
09 2.7142: Utilize higher efficiency lamps and/or ballasts $345 $19 $290
2,345
kWh
- $55
10 2.7142: Utilize higher efficiency lamps and/or ballasts $173 - $91
586
kWh
- $82
11 2.7261: Install timers and/or thermostats $629 $200 $420
3,224
kWh
$209
-
MMBtu
-
TOTAL RECOMMENDED $8,252 $4,791 $7,411
56,858
kWh
$619
-
MMBtu
$222
TOTAL IMPLEMENTED $7,796 $4,663 $7,148
54,806
kWh
$426
-
MMBtu
$222
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs