Assessment Year | 1992 |
---|---|
Principal Product | PLASTIC INJECTION PARTS |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 90 |
Plant Area |
n/a
|
Annual Production | 1,000,000
pieces
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $292,855 | 3,606,096 |
kWh
|
$0.081 |
Natural Gas | $569 | 60 |
MMBtu
|
$9.48 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $30,833 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,707 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $913 | $2,970 |
$913
11,137
kWh
|
- | |
02 | 2.4322: Use or replace with energy efficient substitutes | $17,072 | $3,437 |
$17,072
210,141
kWh
|
- | |
03 | 2.2511: Insulate bare equipment | $6,143 | $297 |
$6,143
75,615
kWh
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $750 | $397 |
$750
9,379
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $287 | $392 |
$357
4,396
kWh
|
$(-70.0) | |
06 | 2.7123: Keep lamps and reflectors clean | $2,507 | $7,150 |
$2,155
26,377
kWh
|
$352 | |
07 | 2.6232: Install set-back timers | $1,480 | $1,520 |
$1,185
14,654
kWh
|
$295 | |
08 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,681 | $800 |
$1,526
18,757
kWh
|
$155 | |
TOTAL RECOMMENDED | $30,833 | $16,963 |
$30,101
370,456
kWh
|
$732 | ||
TOTAL IMPLEMENTED | $3,707 | $10,512 |
$3,425
41,910
kWh
|
$282 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs