Assessment Year | 1992 |
---|---|
Principal Product | PLASTIC BOTTLES |
NAICS |
n/a
|
SIC | 3085: Plastics Bottles |
Sales Range | $10 M to 50M |
# of Employees | 137 |
Plant Area |
n/a
|
Annual Production | 1,396,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $939,475 | 13,777,550 |
kWh
|
$0.068 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,027 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,852 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,527 | $5,750 |
$5,527
81,184
kWh
|
- | |
02 | 2.4221: Install compressor air intakes in coolest locations | $11,072 | $1,266 |
$11,072
162,368
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,852 | - |
$1,852
27,257
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,576 | $196 |
$2,772
40,739
kWh
|
$(-196.0) | |
TOTAL RECOMMENDED | $21,027 | $7,212 |
$21,223
311,548
kWh
|
$(-196.0) | ||
TOTAL IMPLEMENTED | $1,852 | - |
$1,852
27,257
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs