ITAC Assessment: RU0158
ITAC logo
ITAC Assessment: RU0158
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1992
Principal Product VENTILATOR FANS,BLOWERS
NAICS
n/a
SIC 3564: Industrial and Commercial Fans and Blowers and Air Purification Equipment
Sales Range $50
M
to 100
M
# of Employees 140
Plant Area
n/a
Annual Production 25,000
pieces
Production Hrs. Annual 4,160
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $232,228 2,216,002
kWh
Natural Gas $99,252 11,883
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $35,960 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $23,334

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $5,698 $416 $6,115
58,324
kWh
- $(-417.0)
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $9,599 - $9,599
91,442
kWh
- -
03 2.4221: Install compressor air intakes in coolest locations $2,544 $522 $2,544
24,326
kWh
- -
04 2.4231: Reduce the pressure of compressed air to the minimum required $3,516 - $3,516
33,411
kWh
- -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,178 $3,750 $1,178
11,137
kWh
- -
06 2.4312: Improve lubrication practices $1,455 $800 $1,455
13,775
kWh
- -
07 2.2511: Insulate bare equipment $3,066 $1,964 - $3,066
-
MMBtu
-
08 2.3131: Reschedule plant operations or reduce load to avoid peaks $8,904 $2,500 $8,904
-
kWh
- -
TOTAL RECOMMENDED $35,960 $9,952 $33,311
232,415
kWh
$3,066
-
MMBtu
$(-417.0)
TOTAL IMPLEMENTED $23,334 $3,180 $20,685
196,952
kWh
$3,066
-
MMBtu
$(-417.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs