| Assessment Year | 1985 |
|---|---|
| Principal Product | MATTRESSES,BOXSPRINGS |
| NAICS |
n/a
|
| SIC | 2515: Mattresses, Foundations, and Convertible Beds |
| Sales Range | $10 M to 50M |
| # of Employees | 224 |
| Plant Area |
n/a
|
| Annual Production | 240,000
pieces
|
| Production Hrs. Annual | 4,300
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $201,523 | 3,019,050 |
kWh
|
$0.067 |
| Natural Gas | $166,814 | 26,168 |
MMBtu
|
$6.37 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $80,705 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $38,516 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.8114: Change rate schedules or other changes in utility service | $19,896 | $40,000 |
$19,896
-
kWh
|
- | |
| 02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,556 | - |
$2,556
-
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,583 | $2,300 |
$3,181
36,049
kWh
|
$(-598.0)
-
MMBtu
|
|
| 04 | 2.7492: Use proper thickness of insulation on building envelope | $22,293 | $19,340 | - |
$22,293
-
MMBtu
|
|
| 05 | 2.2437: Recover waste heat from equipment | $16,003 | $2,000 |
$12,950
248,828
kWh
|
$3,053
-
MMBtu
|
|
| 06 | 2.7261: Install timers and/or thermostats | $17,374 | $7,500 | - |
$17,374
-
MMBtu
|
|
| TOTAL RECOMMENDED | $80,705 | $71,140 |
$38,583
284,877
kWh
|
$42,122
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $38,516 | $11,800 |
$18,687
284,877
kWh
|
$19,829
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs