Assessment Year | 1992 |
---|---|
Principal Product | DENTAL DRILLS AND BITS |
NAICS |
n/a
|
SIC | 3843: Dental Equipment and Supplies |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
n/a
|
Annual Production | 55,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $144,432 | 1,978,019 |
kWh
|
$0.073 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,855 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,007 | - |
$5,007
68,581
kWh
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,668 | - |
$3,668
50,410
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,010 | $359 |
$5,369
73,564
kWh
|
$(-359.0) | |
04 | 2.2511: Insulate bare equipment | $1,752 | $292 |
$1,752
24,033
kWh
|
- | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $5,637 | - |
$5,637
77,374
kWh
|
- | |
06 | 2.7261: Install timers and/or thermostats | $2,781 | $478 |
$2,781
38,101
kWh
|
- | |
TOTAL RECOMMENDED | $23,855 | $1,129 |
$24,214
332,063
kWh
|
$(-359.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs