ITAC Assessment: RU0144
ITAC logo
ITAC Assessment: RU0144
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1992
Principal Product RAIN GUTTERS
NAICS
n/a
SIC 3444: Sheet Metal Work
Sales Range $10
M
to 50
M
# of Employees 57
Plant Area
n/a
Annual Production 41,700,000
pieces
Production Hrs. Annual 2,275
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $73,843 563,013
kWh
Natural Gas $25,357 3,896
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $8,833 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $1,212

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.4312: Improve lubrication practices $743 $800 $743
5,862
kWh
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $572 $66 $716
5,569
kWh
- $(-144.0)
03 2.4221: Install compressor air intakes in coolest locations $640 $479 $640
4,982
kWh
- -
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $754 $4,750 $754
5,862
kWh
- -
05 2.7221: Lower temperature during the winter season and vice-versa $4,207 - - $4,207
-
MMBtu
-
06 2.7243: Improve air circulation with destratification fans / other methods $1,917 $2,520 $(-288.0)
(-2,345)
kWh
$2,205
-
MMBtu
-
TOTAL RECOMMENDED $8,833 $8,615 $2,565
19,930
kWh
$6,412
-
MMBtu
$(-144.0)
TOTAL IMPLEMENTED $1,212 $545 $1,356
10,551
kWh
- $(-144.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs