Assessment Year | 1992 |
---|---|
Principal Product | RAIN GUTTERS |
NAICS |
n/a
|
SIC | 3444: Sheet Metal Work |
Sales Range | $10 M to 50M |
# of Employees | 57 |
Plant Area |
n/a
|
Annual Production | 41,700,000
pieces
|
Production Hrs. Annual | 2,275
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $73,843 | 563,013 |
kWh
|
$0.13 |
Natural Gas | $25,357 | 3,896 |
MMBtu
|
$6.51 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,833 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,212 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4312: Improve lubrication practices | $743 | $800 |
$743
5,862
kWh
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $572 | $66 |
$716
5,569
kWh
|
- | $(-144.0) | |
03 | 2.4221: Install compressor air intakes in coolest locations | $640 | $479 |
$640
4,982
kWh
|
- | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $754 | $4,750 |
$754
5,862
kWh
|
- | - | |
05 | 2.7221: Lower temperature during the winter season and vice-versa | $4,207 | - | - |
$4,207
-
MMBtu
|
- | |
06 | 2.7243: Improve air circulation with destratification fans / other methods | $1,917 | $2,520 |
$(-288.0)
(-2,345)
kWh
|
$2,205
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $8,833 | $8,615 |
$2,565
19,930
kWh
|
$6,412
-
MMBtu
|
$(-144.0) | ||
TOTAL IMPLEMENTED | $1,212 | $545 |
$1,356
10,551
kWh
|
- | $(-144.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs