| Assessment Year | 1992 |
|---|---|
| Principal Product | RAIN GUTTERS |
| NAICS |
n/a
|
| SIC | 3444: Sheet Metal Work |
| Sales Range | $10 M to 50M |
| # of Employees | 57 |
| Plant Area |
n/a
|
| Annual Production | 41,700,000
pieces
|
| Production Hrs. Annual | 2,275
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $73,843 | 563,013 |
kWh
|
$0.13 |
| Natural Gas | $25,357 | 3,896 |
MMBtu
|
$6.51 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,833 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,212 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4312: Improve lubrication practices | $743 | $800 |
$743
5,862
kWh
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $572 | $66 |
$716
5,569
kWh
|
- | $(-144.0) | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $640 | $479 |
$640
4,982
kWh
|
- | - | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $754 | $4,750 |
$754
5,862
kWh
|
- | - | |
| 05 | 2.7221: Lower temperature during the winter season and vice-versa | $4,207 | - | - |
$4,207
-
MMBtu
|
- | |
| 06 | 2.7243: Improve air circulation with destratification fans / other methods | $1,917 | $2,520 |
$(-288.0)
(-2,345)
kWh
|
$2,205
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $8,833 | $8,615 |
$2,565
19,930
kWh
|
$6,412
-
MMBtu
|
$(-144.0) | ||
| TOTAL IMPLEMENTED | $1,212 | $545 |
$1,356
10,551
kWh
|
- | $(-144.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs