Assessment Year | 1991 |
---|---|
Principal Product | HOME CONSUMER PRODUCTS |
NAICS |
n/a
|
SIC | 3088: Plastics Plumbing Fixtures |
Sales Range | n/a |
# of Employees | 330 |
Plant Area |
n/a
|
Annual Production | 900,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $583,401 | 6,821,805 |
kWh
|
$0.086 |
Natural Gas | $149,588 | 33,498 |
MMBtu
|
$4.47 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $74,946 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $74,946 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $9,136 | - |
$9,136
91,442
kWh
|
- | |
02 | 2.4221: Install compressor air intakes in coolest locations | $1,316 | $267 |
$1,316
15,533
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,917 | $459 |
$3,917
45,721
kWh
|
- | |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $300 | $500 | - |
$300
-
MMBtu
|
|
05 | 2.6212: Turn off equipment during breaks, reduce operating time | $3,648 | - |
$3,648
42,790
kWh
|
- | |
06 | 2.6121: Reduce hot water temperature to the minimum required | $51,300 | - |
$51,300
600,528
kWh
|
- | |
07 | 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown | $5,329 | $900 | - |
$5,329
-
MMBtu
|
|
TOTAL RECOMMENDED | $74,946 | $2,126 |
$69,317
796,014
kWh
|
$5,629
-
MMBtu
|
||
TOTAL IMPLEMENTED | $74,946 | $2,126 |
$69,317
796,014
kWh
|
$5,629
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs