| Assessment Year | 1989 |
|---|---|
| Principal Product | PAPERBOARD & EXTRUSIONS |
| NAICS |
n/a
|
| SIC | 2672: Coated and Laminated Paper, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 90 |
| Plant Area |
n/a
|
| Annual Production | 92,000,000
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | New Jersey |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $166,219 | 1,975,088 |
kWh
|
$0.084 |
| Natural Gas | $18,360 | 3,402 |
MMBtu
|
$5.40 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,031 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,281 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,443 | $650 |
$2,443
29,015
kWh
|
- | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,281 | - |
$3,281
38,980
kWh
|
- | |
| 03 | 2.4312: Improve lubrication practices | $780 | $800 |
$780
9,379
kWh
|
- | |
| 04 | 2.2511: Insulate bare equipment | $2,338 | $218 |
$2,338
27,843
kWh
|
- | |
| 05 | 2.6232: Install set-back timers | $1,089 | $80 |
$1,089
12,896
kWh
|
- | |
| 06 | 2.2414: Use waste heat from hot flue gases to preheat | $2,572 | $3,800 | - |
$2,572
-
MMBtu
|
|
| 07 | 2.7243: Improve air circulation with destratification fans / other methods | $4,528 | $6,660 |
$(-656.0)
(-7,913)
kWh
|
$5,184
-
MMBtu
|
|
| TOTAL RECOMMENDED | $17,031 | $12,208 |
$9,275
110,200
kWh
|
$7,756
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $3,281 | - |
$3,281
38,980
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs