Assessment Year | 1989 |
---|---|
Principal Product | PAPERBOARD & EXTRUSIONS |
NAICS |
n/a
|
SIC | 2672: Coated and Laminated Paper, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 90 |
Plant Area |
n/a
|
Annual Production | 92,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $166,219 | 1,975,088 |
kWh
|
$0.084 |
Natural Gas | $18,360 | 3,402 |
MMBtu
|
$5.40 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,031 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,281 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,443 | $650 |
$2,443
29,015
kWh
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,281 | - |
$3,281
38,980
kWh
|
- | |
03 | 2.4312: Improve lubrication practices | $780 | $800 |
$780
9,379
kWh
|
- | |
04 | 2.2511: Insulate bare equipment | $2,338 | $218 |
$2,338
27,843
kWh
|
- | |
05 | 2.6232: Install set-back timers | $1,089 | $80 |
$1,089
12,896
kWh
|
- | |
06 | 2.2414: Use waste heat from hot flue gases to preheat | $2,572 | $3,800 | - |
$2,572
-
MMBtu
|
|
07 | 2.7243: Improve air circulation with destratification fans / other methods | $4,528 | $6,660 |
$(-656.0)
(-7,913)
kWh
|
$5,184
-
MMBtu
|
|
TOTAL RECOMMENDED | $17,031 | $12,208 |
$9,275
110,200
kWh
|
$7,756
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,281 | - |
$3,281
38,980
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs