Assessment Year | 1989 |
---|---|
Principal Product | PLASTICS POWDERS |
NAICS |
n/a
|
SIC | 3087: Custom Compounding of Purchased Plastics Resins |
Sales Range | $5 M to 10M |
# of Employees | 75 |
Plant Area |
n/a
|
Annual Production | 40,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $595,239 | 8,485,932 |
kWh
|
$0.070 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $41,841 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,215 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $2,570 | $6,745 |
$2,570
44,549
kWh
|
|
02 | 2.4221: Install compressor air intakes in coolest locations | $14,131 | $700 |
$14,131
201,934
kWh
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,084 | - |
$2,084
29,894
kWh
|
|
04 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $2,071 | - |
$2,071
29,601
kWh
|
|
05 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $20,985 | $2,500 |
$20,985
-
kWh
|
|
TOTAL RECOMMENDED | $41,841 | $9,945 |
$41,841
305,978
kWh
|
||
TOTAL IMPLEMENTED | $16,215 | $700 |
$16,215
231,828
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs