Assessment Year | 1989 |
---|---|
Principal Product | STAINLESS STEEL CASTINGS |
NAICS |
n/a
|
SIC | 3325: Steel Foundries, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 31 |
Plant Area |
n/a
|
Annual Production | 420
ton
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $118,598 | 931,125 |
kWh
|
$0.13 |
Natural Gas | $19,033 | 3,690 |
MMBtu
|
$5.16 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $12,558 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,286 | - |
$2,286
18,171
kWh
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,511 | - |
$1,511
12,016
kWh
|
- | - | |
03 | 2.4221: Install compressor air intakes in coolest locations | $2,344 | $49 |
$2,344
18,464
kWh
|
- | - | |
04 | 2.4312: Improve lubrication practices | $1,273 | $800 |
$1,273
9,965
kWh
|
- | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,488 | $2,500 |
$1,488
11,723
kWh
|
- | - | |
06 | 2.2511: Insulate bare equipment | $3,656 | - | - |
$6,906
-
MMBtu
|
$(-3,250.0) | |
TOTAL RECOMMENDED | $12,558 | $3,349 |
$8,902
70,339
kWh
|
$6,906
-
MMBtu
|
$(-3,250.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs