Assessment Year | 1989 |
---|---|
Principal Product | ELECTRICAL FITTINGS |
NAICS |
n/a
|
SIC | 3699: Electrical Machinery, Equipment, and Supplies, Not Elsewhere |
Sales Range | $5 M to 10M |
# of Employees | 80 |
Plant Area |
n/a
|
Annual Production | 1,000,000
lb
|
Production Hrs. Annual | 3,380
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $148,199 | 2,149,472 |
kWh
|
$0.069 |
Natural Gas | $118,430 | 22,151 |
MMBtu
|
$5.35 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $61,316 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,188 | $303 |
$1,188
17,292
kWh
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,288 | - |
$1,288
18,757
kWh
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $1,466 | $474 |
$1,466
21,395
kWh
|
- | |
04 | 2.4322: Use or replace with energy efficient substitutes | $57,374 | $180,000 |
$44,534
646,249
kWh
|
$12,840
-
MMBtu
|
|
TOTAL RECOMMENDED | $61,316 | $180,777 |
$48,476
703,693
kWh
|
$12,840
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs