Assessment Year | 2008 |
---|---|
Principal Product | Analytical instruments |
NAICS | 334516: Analytical Laboratory Instrument Manufacturing |
SIC | 3826: Laboratory Analytical Instruments |
Sales Range | less than $500 k |
# of Employees | 950 |
Plant Area |
216,315
ft2
|
Annual Production | 300,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $237,822 | 7,744,800 |
kWh
|
$0.031 |
Electricity Demand | $132,522 | 15,596 |
kW-mo/yr
|
$8.50 |
Electricity Fees | $2,197 | - |
|
- |
Natural Gas | $104,097 | 12,909 |
MMBtu
|
$8.06 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,170 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,260 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,580 | $1,500 |
$1,900
60,500
kWh
|
$680
-
kW-mo/yr
|
- | - | |
02 | 2.6218: Turn off equipment when not in use | $1,670 | $1,000 |
$1,670
53,000
kWh
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,010 | $12,000 |
$7,550
239,800
kWh
|
$2,840
-
kW-mo/yr
|
- | $(-380.0) | |
04 | 2.9112: Use solar heat to heat water | $3,910 | $84,000 | - | - |
$3,910
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $18,170 | $98,500 |
$11,120
353,300
kWh
|
$3,520
-
kW-mo/yr
|
$3,910
-
MMBtu
|
$(-380.0) | ||
TOTAL IMPLEMENTED | $14,260 | $14,500 |
$11,120
353,300
kWh
|
$3,520
-
kW-mo/yr
|
- | $(-380.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs