Assessment Year | 1989 |
---|---|
Principal Product | CORRUGATED CARTONS |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 55 |
Plant Area |
n/a
|
Annual Production | 350,000
thousand feet
|
Production Hrs. Annual | 2,120
hrs
|
Location (State) | Delaware |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $199,854 | 2,317,995 |
kWh
|
$0.086 |
Natural Gas | $146,515 | 34,008 |
MMBtu
|
$4.31 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $34,093 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,785 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4325: Upgrade conveyors | $25,065 | $45,500 |
$10,204
118,699
kWh
|
$14,861
-
MMBtu
|
|
02 | 2.7243: Improve air circulation with destratification fans / other methods | $3,434 | $4,320 |
$(-436.0)
(-4,982)
kWh
|
$3,870
-
MMBtu
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $970 | $298 |
$970
11,430
kWh
|
- | |
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $2,276 | - |
$2,276
26,377
kWh
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,839 | $1,600 |
$1,839
21,395
kWh
|
- | |
06 | 2.4221: Install compressor air intakes in coolest locations | $509 | $168 |
$509
5,862
kWh
|
- | |
TOTAL RECOMMENDED | $34,093 | $51,886 |
$15,362
178,781
kWh
|
$18,731
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,785 | $168 |
$2,785
32,239
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs