Assessment Year | 1989 |
---|---|
Principal Product | VALVES & STEAM TRAPS |
NAICS |
n/a
|
SIC | 3494: Valves and Pipe Fittings, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 500 |
Plant Area |
n/a
|
Annual Production | 190,000
pieces
|
Production Hrs. Annual | 6,448
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $506,708 | 7,033,998 |
kWh
|
$0.072 |
Natural Gas | $48,873 | 9,221 |
MMBtu
|
$5.30 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $45,285 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $42,078 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,065 | $18,865 |
$14,065
195,487
kWh
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,476 | $320 |
$6,476
89,977
kWh
|
- | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $11,518 | $5,800 |
$11,518
160,023
kWh
|
- | |
04 | 2.4312: Improve lubrication practices | $3,207 | $800 |
$3,207
44,549
kWh
|
- | |
05 | 2.4221: Install compressor air intakes in coolest locations | $1,129 | $302 |
$1,129
15,826
kWh
|
- | |
06 | 2.4133: Use most efficient type of electric motors | $8,508 | $7,568 |
$8,508
118,113
kWh
|
- | |
07 | 2.1233: Analyze flue gas for proper air/fuel ratio | $382 | $500 | - |
$382
-
MMBtu
|
|
TOTAL RECOMMENDED | $45,285 | $34,155 |
$44,903
623,975
kWh
|
$382
-
MMBtu
|
||
TOTAL IMPLEMENTED | $42,078 | $33,355 |
$41,696
579,426
kWh
|
$382
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs