Assessment Year | 1989 |
---|---|
Principal Product | INDUS. ELECT. FURNACES |
NAICS |
n/a
|
SIC | 3567: Industrial Process Furnaces and Ovens |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
n/a
|
Annual Production | 15
pieces
|
Production Hrs. Annual | 3,432
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $89,402 | 880,129 |
kWh
|
$0.10 |
Natural Gas | $19,881 | 3,972 |
MMBtu
|
$5.01 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,729 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $484 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $221 | $159 |
$221
2,052
kWh
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $212 | - |
$212
2,052
kWh
|
- | |
03 | 2.4312: Improve lubrication practices | $173 | $600 |
$173
1,758
kWh
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $272 | - |
$272
2,638
kWh
|
- | |
05 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $5,484 | $1,000 |
$5,484
-
kWh
|
- | |
06 | 2.7243: Improve air circulation with destratification fans / other methods | $1,367 | $1,440 |
$(-323.0)
(-3,224)
kWh
|
$1,690
-
MMBtu
|
|
TOTAL RECOMMENDED | $7,729 | $3,199 |
$6,039
5,276
kWh
|
$1,690
-
MMBtu
|
||
TOTAL IMPLEMENTED | $484 | - |
$484
4,690
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |